Asphalt Test Resultsm K-CC7r TESTING SERVICE. INC.
118 MADISON RD, PO BOX 177 VAN BUREN,
Date: May 25, 2021
Project: Legacy Place; Phase II
Engineer:
Contractor: Franklin Construction
TYPE MATERIAL: Type III Surface
TEST NO. LOCATION
ARK 72957 479-474-2075 Fax 479-474-2984
ASPHALTIC CONCRETE
FIELD DENSITY DETERMINATION
1 Thistle; Station 0+70, 4' East of Centerline
2 Thistle; Station 5+50, 6' West of Centerline
3 Aster; Station 0+80, 3' South of Centerline
4 Aster; Station 4+00, 7' North of Centerline
5 Barberry; Station 6+60, 4' West of Centerline
DATE OF PLACEMENT:
TEST NO.
1
2
3
4
5
DATE OF TEST
5/25/21
5/25/21
5/25/21
5/25/21
5/25/21
DENSITY OF SAMPLE Ibs/cu.ft.
138.0
142.4
142.3
142.4
139.3
MAXIMUM THEORETICAL
148.5
148.5
148.5
148.5
148.5
% COMPACTION OF SAMPLE
92.9
95.9
95.8
95.9
93.8
%COMPACTION SPECIFIED
92-96
92-96
92-96
92-96
92-96
DEPTH OF CORE (inches)
2.6
3.5
2.9
3.0 1
3.0