Asphalt Test Resultsm K-CC7r TESTING SERVICE. INC. 118 MADISON RD, PO BOX 177 VAN BUREN, Date: May 25, 2021 Project: Legacy Place; Phase II Engineer: Contractor: Franklin Construction TYPE MATERIAL: Type III Surface TEST NO. LOCATION ARK 72957 479-474-2075 Fax 479-474-2984 ASPHALTIC CONCRETE FIELD DENSITY DETERMINATION 1 Thistle; Station 0+70, 4' East of Centerline 2 Thistle; Station 5+50, 6' West of Centerline 3 Aster; Station 0+80, 3' South of Centerline 4 Aster; Station 4+00, 7' North of Centerline 5 Barberry; Station 6+60, 4' West of Centerline DATE OF PLACEMENT: TEST NO. 1 2 3 4 5 DATE OF TEST 5/25/21 5/25/21 5/25/21 5/25/21 5/25/21 DENSITY OF SAMPLE Ibs/cu.ft. 138.0 142.4 142.3 142.4 139.3 MAXIMUM THEORETICAL 148.5 148.5 148.5 148.5 148.5 % COMPACTION OF SAMPLE 92.9 95.9 95.8 95.9 93.8 %COMPACTION SPECIFIED 92-96 92-96 92-96 92-96 92-96 DEPTH OF CORE (inches) 2.6 3.5 2.9 3.0 1 3.0